Edge Cell E32
Thirty-two GPUs at the edge.
Four Rack R8 systems in one ten-foot module, air-cooled, for regional inference, computer vision and visualisation close to where the data is made. It arrives on one truck and needs no outside plant.

Styling concept. Configuration not finalised.
StatusBudgetary architecture. Mechanical and thermal release pending.
Questions first? Ask the team about Edge Cell E32
A closer look.
One ten-foot module: compute, cooling, power and fire protection inside the sleeve.
Styling concepts from the HYPERCUBE Product Family Design Collection, Edition 3. Configuration not finalised; renders do not depict a supplied configuration.
Two configurations.
The RTX PRO 6000 reference, and a proposed B300 option in the same ten-foot module.
| Specification | RTX PRO 6000 edition, E32 | B300 option, E16 (proposed) |
|---|---|---|
| GPUs | 32 RTX PRO 6000 Blackwell Server Edition | 16 Blackwell Ultra B300 |
| Systems | 4 Rack R8, one eight-GPU server each | 2 HGX B300 eight-GPU nodes |
| Host CPUs | 4 dual-socket x86 hosts, 1 to 2 TB memory each | 2 dual-socket x86 hosts |
| FP4 AI compute | 128,000 AI TOPS sparse; 4,000 per GPU | 288 PF sparse; 216 PF dense |
| GPU memory | 3.07 TB GDDR7 ECC: 96 GB per GPU at 1.6 TB/s | 4.2 TB HBM3e: 2.1 TB per node |
| GPU interconnect | PCIe; 32 independent GPUs | NVLink 5 in each node: 1.8 TB/s per GPU |
| Network | 100, 200 or 400 GbE serving fabric | 1.6 TB/s scale-out per node |
| Storage | 100 to 500 TB usable NVMe | 100 to 500 TB usable NVMe |
| IT power | 25 to 40 kW design envelope | About 30 kW, planning allowance |
| Cooling | Air: two precision wall units | Air-cooled nodes; thermal validation required |
| Status | Budgetary architecture; engineering release pending | Proposed; outside Portfolio 2026 |
There is no Vera Rubin Edge Cell: the Rubin platforms are liquid-cooled and the ten-foot body carries no coolant loop. Aggregate GPU memory is the sum of independent GPUs, not one pool. The B300 option is proposed and subject to thermal validation. Reference figures from the HYPERCUBE Product Family Design Collection, Edition 3, and NVIDIA published platform data. They are budgetary and indicative, not a supplier quotation. Final configuration, pricing, availability and delivery are confirmed by quotation for a named country and end user. Images are styling concepts.
What goes in.
Nothing outside the module: cooling, power, fire and access are all inside the sleeve.
Modules and packages
- 1 Ten-foot module
- 2.99 × 2.44 × 2.90 m, ISO footprint, high-cube height
What the site provides
- Low-voltage supply sized to the IT envelope and the air units
- Fibre uplink to the customer network
- No water: the cell is air-cooled
- Level concrete pad or steel skid, truck and crane access
| Item | Qty | What it is |
|---|---|---|
| Rack R8 systemsR1 to R4 | 4 | Each: one eight-GPU server with a dual-socket x86 host, 1 to 2 TB memory, 60 to 120 TB NVMe and a top-of-rack switch |
| RTX PRO 6000 Blackwell Server Edition | 32 | 96 GB GDDR7 ECC each, passively cooled, eight per Rack R8 |
| Precision air units | 2 | Wall-mounted on the far end wall; condensers in the graphite end |
| Power cabinet | 1 | Distribution, metering and lithium UPS ride-through |
| Clean-agent fire suppression | 1 | Cylinder with detection, beside the entrance |
| Overhead cable tray | 1 | Serving network and out-of-band management |
| Access control | 1 | At the entrance in the near graphite end |
Options.
Chosen at quotation and fixed in the bill of materials for the edition ordered. Prices are given by quotation.
Compute
- E32: four Rack R8 with 32 RTX PRO 6000 Server Edition, the reference
- E16: two HGX B300 nodes, proposed
- Two or three Rack R8 for a phased start, plant sized for four
Storage
- 100, 250 or 500 TB usable NVMe
- Local replication to a second cell
Network
- 100, 200 or 400 GbE serving fabric
- Single or dual uplinks to the customer network
- Out-of-band management network
Power and autonomy
- Lithium UPS ride-through sized to the site's generator start
- Single or dual utility feed
- Generator connection in the graphite end
Cooling and climate
- Air units sized to the design ambient of the site
- Hot-climate or cold-climate package
- Intake and condenser clearances confirmed on site
Security
- Access control at the entrance
- CCTV and intrusion detection
- Telemetry under customer control
Site and services
- Concrete pad or steel skid
- Factory acceptance before shipping, site acceptance on arrival
- In-country support and spares
Finish
- Pearl white sleeve, the reference finish
- Graphite sleeve with a white logo
- Titanium-grey sleeve for coastal and industrial sites
Best fit.
Where Edge Cell E32 earns its place.
- Telecom and industrial edge inference
- Regional AI services and virtual workstations
- Computer vision at ports, airports and factories
- Digital twins and multi-user visualisation close to the data
Price Edge Cell E32 for your site.
Tell us the quantity, the delivery country and the timing. We reply with a written quotation: price, lead time and delivery terms.